 Transformer Load Monitor

Description
An all electronic, microprocessor controlled,
digital watthour/demand meter for
monitoring the load performance of transformers located
on utility poles and in sub-surface vaults.
Technical Specifications
Accuracy
ANSI C12.16 Electronic Meter Standards, +/- 0.5% full
scale
Power Input
Types:
2-wire or 3-wire single phase
3-phase, 4-wire WYE
3-phase, 3-wire DELTA
Voltages: 120V, 240V,
120/240V
120/208V, 277/480V
Frequency: 60Hz
(other configurations available, please inquire)
Operating Ranges
Voltage:
+/- 20% of rated voltage
Current:
5A secondary
Frequency: 57Hz to 63Hz
Temperature: -40 C to +85 C
Humidity: 0 to 95%
non-condensing
Non-Volatile Memory
32k ROM, 512 bytes EEPROM, 32k RAM
Data is stored and secured in the event of a power
failure for a minimum of 3 years
Liquid Crystal Display
Preprogrammed at factory to display automatically and
sequentially every 5 seconds:
Meter Number, Location Code Date, Time, voltage per
phase, kWh, kW (15 or 30 minute integration
interval), ambient temperature, transformer temperature,
wind speed.
Additional programmable display: serial #, current per
phase, instantaneous kW per phase, water level.
30 Day Daily History
Factory programmed to record and store 30 day daily
kW and kWh history in non-volatile memory
60 Day Hourly History
Factory programmed to record and store hourly kWh,
kW, voltage and current per phase, 2 temperatures, wind
speed, for the past 60 days
Event Log Reporting
Factory programmed to record the following events
with date/time and maintain the 20 latest occurrences of
each in non-volatile memory:
Voltage exceeds or drops below parameters
Change in voltage exceeds a parameter
Instantaneous kW exceeds a parameter
Temperature exceeds or drops below parameters
Wind speed exceeds a parameter
Water level exceeds a parameter
All parameters are user definable and configurable.
Time-Of-Day Recording
Up to 3 time periods (user programmable)
Digital Input
3 inputs 0-5V, plus/negative logic acceptable,
opto-isolated
Analog Input
2 input 0-5V, 10k-ohm input impedance
Relay Controlled Output
SPST switch, 1A/125VAC
TELCO Communications
1200 baud modem built-in, FCC Part 68 registered DAA,
Bell 212A/103 and CCITT V.22 standards, AT
command set compatible, automatic answer, speed, parity
Installation
Mounting:
S-Base, A-Base (numerous configurations)
Potential Wire Type/Sizes: 14 to
18 gauge, solid or stranded
Data
Cable:
22 gauge, 4 conductor
Current Transformer Wire: 14 to
20 gauge
Enclosure
12 x 10 x 5 surface mount, steel,
lockable, hinged, NEMA/EEMAC Type 12 and Type 13 (Type 3
and Type 4 also available), UL 50 Type 12 and Type 13,
JIC standard EGP-I-1967, CSA Type 12, IEC 529, IP65
Other Outstanding Features
Field Programmable, kW reset button, kW/kWh reset
button, RS-232 communications, RS-422 communications, RF
and Cellular Phone communications expandable, password
protected, spike and surge protected, fuse protected
circuitry, real time clock.
Note: Specifications are subject to change
without notice due to circumstances and availability of
materials beyond our control. However, basic
specifications regarding operation and accuracy will be
maintained at all times.